Precautions for sensor switches edit broadcast

Nov 15, 2021

The sensor switch works by detecting the presence or absence of infrared rays of the human body, and is generally installed indoors. The false alarm rate of the human body sensor switch is greatly related to the installation location and method. The following points should be paid attention to when installing the human body sensor switch:

1. Do not operate with power during installation, wait for the installation to complete before powering on.

2. Do not use it beyond the power range.

3. The top-mounted human body induction switch should not be too high from the ground, preferably between 2.4-3.1 meters. The wall-mounted human body sensor switch can be installed in the original switch position for direct replacement.

4. When installing the human body sensor switch, it should be far away from the place where the air temperature changes such as heating, air conditioner, refrigerator, stove and so on.

5. There shall be no screens, furniture, large bonsai or other partitions within the detection range of the sensor switch.

6. Do not switch the switch directly to the window, to prevent the disturbance of hot air outside the window and the movement of people from causing false alarms.

7. Do not install the switch in places with strong air currents such as doorways and air ducts.